Kidde 0919-9999/ RF-SM-DC Battery-Operated Wireless Interconnectable Smoke Alarm
|
![]() | ||||
| ||||
![]() |
![]() An interconnected system provides more warnings in more places in case of smoke or fire in your home. |
![]() The Kidde Wireless System alarms have a hush button to silence nuisance alarms. View larger. |
Step 1 - Determine the type of smoke alarms currently installed in your house.
1. Battery Powered
No wires; runs only on batteries.
Most older homes have battery-powered smoke alarms. These alarms have no protruding wires and are battery powered.
2. Hardwired
Runs on your home's electricity and may have battery backup. Only one alarm sounds when test button is pressed.
If your home was built in the last 20 years, you probably have hardwired smoke alarms. If only the alarm that you test sounds, then you do not have an interconnected system.
3. Interconnected
Runs on your home's electricity and may have battery backup. All alarms sound when one test button is pressed.
Homes built in the last 15 years may have an interconnected smoke alarm system. If all alarms sound when you test, you have an interconnected system.
Step 2 - Decide how many alarms you need in your home.
The NFPA recommends at least one smoke alarm on every level of the home and in every sleeping area.
Step 3 - Based on your home's current alarm set-up, decide which Kidde Wireless alarms to purchase.
1. If your home has only battery powered alarms:
Purchase enough Kidde Wireless Battery Powered Smoke Alarms (0919-9999) to replace all of your current smoke alarms. You will also have the ability to add Kidde Wireless Battery Powered Alarms in additional rooms for expanded coverage.
2. If your home has only hardwired smoke alarms:
Purchase enough Kidde Wireless AC Powered Smoke Alarms (1279-9999) to replace all of your current smoke alarms. You will also have the ability to add Kidde Wireless Battery Powered Alarms in additional rooms for expanded coverage.
3. If your home has interconnected smoke alarms:
Purchase one Kidde Wireless AC Powered Smoke Alarms to replace one current smoke alarm. Kidde Wireless Battery Powered Alarms can then be installed in additional rooms.
Interconnectable for Improved Safety
Fire and consumer experts recommend interconnected alarms for added protection. According to the National Fire Protection Association (NFPA), most Americans feel they are more at risk of being a victim of a tornado than of a house fire. Actually the opposite is true. Fires are more common than any other disaster that strikes a family at home, and can become deadly in minutes.
You have on average less than three minutes from the time you hear a smoke alarm to escape a fire. The sooner you hear an alarm, the sooner you can get out safely. Smoke alarms that link together so that when one goes off, they all go off, are called interconnected alarms. These alarms provide more warnings in more places, giving your family more time to escape a house fire. Houses built after 1993 are required by building codes to have interconnected alarms that are wired into their electrical system.
Trademarked Hush Feature for Convenience
By pressing the Hush button, you can easily and safely silence nuisance alarms caused by non-emergency situations, such as overcooked dinners.
This alarm's Smart Hush feature has the capability of temporarily desensitizing the alarm circuit for up to 8 minutes. This feature is to be used only when a known alarm condition, such as smoke from cooking, activates the alarm. The smoke alarm is desensitized by pushing the Test/Hush button on the smoke alarm cover. If the smoke is not too dense, the alarm will silence immediately. The red LED will illuminate for 1.5 seconds every 8 seconds while in hush. This indicates that the alarm is in a temporarily desensitized condition. The smoke alarm will automatically reset after approximately 8 minutes and sound the alarm if particles of combustion are still present. Smart Hush can be used repeatedly until the air has been cleared of the condition causing the alarm. Pushing the Test/Hush button on the alarm will end the hush period.
3-AA Batteries, Indicator LED, and Test Feature
Because a smoke alarm only helps protect you if it's working, this unit features a red LED that flashes every 10 seconds to indicate that it is operating correctly. For additional peace of mind, the alarm also contains a test/reset button that enables you to periodically test its circuitry and horn.
The alarm's 3-AA batteries provide continuous protection against smoke and fire hazards, even during power outages. The unit offers a low battery warning that issues a brief chirp every 30 to 40 seconds for at least seven days before losing power, letting you know that it's time to change the battery.
This alarm is UL listed, so you can be confident of its quality, and it is backed by a 10-year limited warranty that lasts the life of the alarm.
About Kidde: A UTC Fire & Security Brand
Renowned for global leadership in fire detection and suppression, Kidde provides solutions ranging from portable fire extinguishers to advanced industrial controls such as flame detection and explosion suppression systems.
Kidde is a UTC Fire & Security brand, with a history that's rich with innovations, from the patent of the Chubb Detector Lock in 1818 to the development of the world's first wireless networked smoke detectors in 2004.
What's in the Box
One 0919-9999 smoke alarm with mounting bracket and mounting hardware, 3- AA batteries, a 10-year limited warranty and a bilingual user's manual.
DuPont Self-Charging Smoke Alarm Model PS-131 Smoke Detector
SYSTEM SENSOR BEAM1224S S.SENSOR 4-WIRE BEAM W/ INTECLE
SYSTEM SENSOR 2WTR-B 2W, 12/ 24 VDC, THERM., RELAY, W/ BASE
GENTEX 9123TF 9123TF
System Sensor SW SpectrAlert Advance Fire Alarm Strobe, White
Direct Wire Smoke Alarm
Firex DC Powered Smoke Alarm
SILENT KNIGHT SD505-6SB SOUNDER BASE FOR AHS AIS APS HEAD
System Sensor 2W-B i3 Series 2-wire, Photoelectric i3 Smoke Detector
Firex 480 Photoelectric Smoke Detector Alarm, 9V DC Battery Powered
Kidde KN-COP-IC Hardwire Carbon Monoxide Alarm with Battery Backup and Digital Display, Interconnectable
First Alert SCO501CN-3ST (Series SCO500) ONELINK Battery Operated Combination Smoke and Carbon Monoxide Alarm with Voice Location
Kidde KN-COPP-B Front Load Battery-Operated Carbon Monoxide Alarm with Digital Display
Kidde HD135F Fyrnetics Hardwire Heat Detector with Battery Backup
Kidde KN-COSM-IB Hardwire Combination Carbon Monoxide and Smoke Alarm with Battery Backup and Voice Warning, Interconnectable
Kidde PI2010 Smoke Alarm Dual Sensor with Battery Backup, White
Kidde 1279-9999/ RF-SM-AC Hardwire Smoke Alarm with Battery Backup, Interconnectable
Kidde KN-COPP-B-LPM Battery-Operated Carbon Monoxide Alarm with Digital Display
Kidde KN-COSM-XTR-B Nighthawk Combination Carbon Monoxide, Fire, and Smoke Intelligent Alarm
First Alert SA320CN Double Sensor Battery-Powered Smoke and Fire Alarm